Online 1:1 Transformer less UPS
The transformer‑less single‑phase input, single‑phase output online double conversion UPS delivers seamless power protection with advanced features including cold start capability, generator compatibility, and a hot‑swappable battery system for easy maintenance without interruption. Its rack/tower convertible design and versatile LCD interface make it adaptable for diverse installations, while a high input power factor of 0.99 with PFC and ECO mode operation maximize energy efficiency. With a wide input voltage range, selectable output options, and a smart charger to optimize battery performance, the system ensures flexibility and reliability. Multiple communication interfaces and robust safeguards against short circuits, overloads, and overheating further enhance its dependability, making it ideal for critical applications requiring continuous and efficient power management.
Choose your Model
Technical Specification
Single Phase 230VAC-1000Va E series Online Double Conversion UPS, Rack Model
Capacity (VA/Watts): 1000VA/900W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~300Vac (176~280Vac @ 100% load) |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤3% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 4ms (Typical) |
| Output Waveform | Pure Sinewave |
| Output Frequency Line Mode | 46~54Hz or 56~64Hz |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 50dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery type & number | 9AH, 2nos |
| Typical recharge time | 4 hours (to 90% of full capacity) |
| Charging voltage | 27.4Vdc ±1% |
| Charging current (Max) | 1A |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 11.3 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 325 mm |
Features
- Cold start
- Generator compatible
- Hot-Swappable battery design
- Rack/Tower convertible design
- Intelligent fan speed regulation
- Input power factor 0.99 with PFC
- Load segment settable (Optional)
- Emergency power off function (EPO)
- Wide input voltage range:110~300Vac
- ECO mode operation for energy saving
- Versatile LCD human-computer interface
- Online double conversion with full digital control
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-1000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger
Capacity (VA/Watts): 1000VA/900W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~300Vac (176~280Vac @ 100% load) |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤3% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 4ms (Typical) |
| Output Waveform | Pure Sinewave |
| Output Frequency Line Mode | 46~54Hz or 56~64Hz |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 50dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Typical recharge time | 4 hours (to 90% of full capacity) |
| Charging voltage | 27.4Vdc ±1% |
| Charging current (Max) | 6A/12A |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 5.6 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 325 mm |
Features
- Cold start
- Generator compatible
- Hot-Swappable battery design
- Rack/Tower convertible design
- Intelligent fan speed regulation
- Input power factor 0.99 with PFC
- Load segment settable (Optional)
- Emergency power off function (EPO)
- Wide input voltage range:110~300Vac
- ECO mode operation for energy saving
- Versatile LCD human-computer interface
- Online double conversion with full digital control
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-2000Va Online Double Conversion UPS, Rack/Tower Convertible Model
Capacity (VA/Watts): 2000VA/1800W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~300Vac (176~280Vac @ 100% load) |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Output Frequency Line Mode | 46~54Hz or 56~64Hz |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| AC Voltage Regulation Batt Mode | 0ms |
| Frequency Range Batt Mode | 4ms (Typical) |
| Waveform (Batt. Mode) | Pure Sinewave |
| Harmonic distortion (THD) | ≤3% Linear load ≤5% Non linear load |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 4ms (Typical) |
| Output Waveform | Pure Sinewave |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | 1500m |
| Noise level | Less than 50dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery type & number | 9AH & 4nos |
| Typical recharge time | 4 hours (to 90% of full capacity) |
| Charging voltage | 54.8Vdc ±1% |
| Charging current (Max) | 1A |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 19.5 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 460 mm |
Features
- Cold start
- Generator compatible
- Hot-Swappable battery design
- Rack/Tower convertible design
- Intelligent fan speed regulation
- Input power factor 0.99 with PFC
- Load segment settable (Optional)
- Emergency power off function (EPO)
- Wide input voltage range:110~300Vac
- ECO mode operation for energy saving
- Versatile LCD human-computer interface
- Online double conversion with full digital control
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-2000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger
Capacity (VA/Watts): 2000VA/1800W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~300Vac (176~280Vac @ 100% load) |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤3% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Output Frequency Line Mode | 46~54Hz or 56~64Hz |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| AC Voltage Regulation Batt Mode | 0ms |
| Frequency Range Batt Mode | 4ms (Typical) |
| Waveform (Batt. Mode) | Pure Sinewave |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 50dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Typical recharge time | 4 hours (to 90% of full capacity) |
| Charging voltage | 54.8Vdc ±1% |
| Charging current (Max) | 6A/12A |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 10.5 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 600 mm |
Features
- Cold start
- Generator compatible
- Hot-Swappable battery design
- Rack/Tower convertible design
- Intelligent fan speed regulation
- Input power factor 0.99 with PFC
- Load segment settable (Optional)
- Emergency power off function (EPO)
- Wide input voltage range:110~300Vac
- ECO mode operation for energy saving
- Versatile LCD human-computer interface
- Online double conversion with full digital control
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-3000Va Online Double Conversion UPS, Rack/Tower Convertible Model
Capacity (VA/Watts): 3000VA/2700W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~300Vac (176~280Vac @ 100% load) |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤3% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 4ms (Typical) |
| Output Waveform | Pure Sinewave |
| Output Frequency Line Mode | 46~54Hz or 56~64Hz |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 50dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery type & number | 9AH & 6nos |
| Typical recharge time | 4 hours (to 90% of full capacity) |
| Charging voltage | 82.2Vdc ±1% |
| Charging current (Max) | 1A |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 26 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 600 mm |
Features
- Cold start
- Generator compatible
- Hot-Swappable battery design
- Rack/Tower convertible design
- Intelligent fan speed regulation
- Input power factor 0.99 with PFC
- Load segment settable (Optional)
- Emergency power off function (EPO)
- Wide input voltage range:110~300Vac
- ECO mode operation for energy saving
- Versatile LCD human-computer interface
- Online double conversion with full digital control
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-3000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger
Capacity (VA/Watts): 3000VA/2700W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~300Vac (176~280Vac @ 100% load) |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤3% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 4ms (Typical) |
| Output Waveform | Pure Sinewave |
| Output Frequency Line Mode | 46~54Hz or 56~64Hz |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | 1500m |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Typical recharge time | 4 hours (to 90% of full capacity) |
| Charging voltage | 82.2Vdc ±1% |
| Charging current (Max) | 6A/12A |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 11 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 600 mm |
Features
- Cold start
- Generator compatible
- Hot-Swappable battery design
- Rack/Tower convertible design
- Intelligent fan speed regulation
- Input power factor 0.99 with PFC
- Load segment settable (Optional)
- Emergency power off function (EPO)
- Wide input voltage range:110~300Vac
- ECO mode operation for energy saving
- Versatile LCD human-computer interface
- Online double conversion with full digital control
- Selectable output voltage: 208/220/230/240Vac
- Smart charger design for optimized battery performance
- Maximum charging current can be expanded to 12A (Long run unit)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-6000Va Online Double Conversion UPS, Tower Model
Capacity (VA/Watts): 6000VA/5400W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~286Vac |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Bypass voltage range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤2% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 0ms |
| Output Waveform | Pure Sinewave |
| Overload Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately |
| Overload Bypass Mode | 40A (Breaker) |
| Efficiency | 93.5% |
| Output Frequency Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 55dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery Voltage | ±120Vdc |
| Battery type & number | 9AH & 20nos |
| Typical recharge time | 6~8 hours (to 90% of full capacity) |
| Charging current (Max) | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 70 Kg |
| Height | 720 mm |
| Width | 191 mm |
| Length | 460 mm |
Features
- Cold start
- Generator compatible
- Wide input frequency range
- Self-testing when UPS startup
- Intelligent fan speed regulation
- Maximum charging current up to 10A
- Wide input voltage range:110~286Vac
- ECO mode operation for energy saving
- Design with maintenance switch (Optional)
- Selectable output voltage:208/220/230/240Vac
- Online double conversion with full digital control
- N+X parallel redundancy, support maximum 4 units in parallel
- Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-6000Va Online Double Conversion UPS, Tower Model with extended charger
Capacity (VA/Watts): 6000VA/5400W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~286Vac |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Bypass voltage range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤2% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 0ms |
| Output Waveform | Pure Sinewave |
| Overload Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately |
| Overload Bypass Mode | 40A (Breaker) |
| Efficiency | 93.5% |
| Output Frequency Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 55dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery Voltage | ±96/±108/±120Vdc (Adjustable) |
| Typical recharge time | 6~8 hours (to 90% of full capacity) |
| Charging current (Max) | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 12.5 Kg |
| Height | 337 mm |
| Width | 191 mm |
| Length | 460 mm |
Features
- Cold start
- Generator compatible
- Wide input frequency range
- Self-testing when UPS startup
- Intelligent fan speed regulation
- Maximum charging current up to 10A
- Wide input voltage range:110~286Vac
- ECO mode operation for energy saving
- Design with maintenance switch (Optional)
- Selectable output voltage:208/220/230/240Vac
- Online double conversion with full digital control
- N+X parallel redundancy, support maximum 4 units in parallel
- Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-6000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger
Capacity (VA/Watts): 6000VA/5400W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~286Vac |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Bypass voltage range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤2% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 0ms |
| Output Waveform | Pure Sinewave |
| Overload Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately |
| Overload Bypass Mode | 40A (Breaker) |
| Efficiency | 94% |
| Output Frequency Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 55dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery Voltage | ±120Vdc |
| Typical recharge time | 6~8 hours (to 90% of full capacity) |
| Charging current (Max) | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 16 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 625 mm |
Features
- Cold start
- Parallel kit default
- High power density
- Generator compatible
- Wide input frequency range
- Self-testing when UPS startup
- Intelligent fan speed regulation
- Maximum charging current up to 10A
- Wide input voltage range:110~286Vac
- ECO mode operation for energy saving
- LCD supports Rack/Tower convertible design
- Online double conversion with full digital control
- N+X parallel redundancy, support maximum 4 units in parallel
- Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-10000Va Online Double Conversion UPS, Tower Model
Capacity (VA/Watts): 10000VA/9000W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~286Vac |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Bypass voltage range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤2% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 0ms |
| Output Waveform | Pure Sinewave |
| Overload Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately |
| Overload Bypass Mode | 63A (Breaker) |
| Efficiency | 93.5% |
| Output Frequency Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 58dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery Voltage | ±120Vdc |
| Typical recharge time | 6~8 hours (to 90% of full capacity) |
| Charging current (Max) | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 71.5 Kg |
| Height | 720 mm |
| Width | 191 mm |
| Length | 460 mm |
Features
- Cold start
- Generator compatible
- Wide input frequency range
- Self-testing when UPS startup
- Intelligent fan speed regulation
- Maximum charging current up to 10A
- Wide input voltage range:110~286Vac
- ECO mode operation for energy saving
- Design with maintenance switch (Optional)
- Selectable output voltage:208/220/230/240Vac
- Online double conversion with full digital control
- N+X parallel redundancy, support maximum 4 units in parallel
- Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-10000Va Online Double Conversion UPS, Tower Model with extended charger
Capacity (VA/Watts): 10000VA/9000W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~286Vac |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Bypass voltage range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤2% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 0ms |
| Output Waveform | Pure Sinewave |
| Overload Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately |
| Overload Bypass Mode | 63A (Breaker) |
| Efficiency | 93.5% |
| Output Frequency Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery Voltage | ±96/±108/±120Vdc (Adjustable) |
| Typical recharge time | 6~8 hours (to 90% of full capacity) |
| Charging current (Max) | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 14 Kg |
| Height | 337 mm |
| Width | 191 mm |
| Length | 460 mm |
Features
- Cold start
- Generator compatible
- Wide input frequency range
- Self-testing when UPS startup
- Intelligent fan speed regulation
- Maximum charging current up to 10A
- Wide input voltage range:110~286Vac
- ECO mode operation for energy saving
- Design with maintenance switch (Optional)
- Selectable output voltage:208/220/230/240Vac
- Online double conversion with full digital control
- N+X parallel redundancy, support maximum 4 units in parallel
- Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Technical Specification
Single Phase 230VAC-10000Va Online Double Conversion UPS, Rack/Tower Convertible Model
Capacity (VA/Watts): 10000VA/9000W
| Input | |
|---|---|
| Nominal voltage | 208/220/230/240Vac |
| Operating voltage range | 110~286Vac |
| Operating frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
| Power Factor | ≥0.99 |
| Bypass voltage range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%) |
| Output | |
|---|---|
| Output voltage | 208/220/230/240Vac |
| Crest factor | 3:1 |
| Harmonic distortion (THD) | ≤2% Linear load ≤5% Non linear load |
| Power Factor | 0.9 |
| Voltage Regulation | ± 1% |
| Transfer Time AC Mode to Batt Mode | 0ms |
| Transfer Time Inverter to Bypass | 0ms |
| Output Waveform | Pure Sinewave |
| Overload Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately |
| Overload Bypass Mode | 63A (Breaker) |
| Efficiency | 94% |
| Output Frequency Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) |
| Output Frequency Bat. Mode | (50/60±0.1%)Hz |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -25°C ~ 55°C |
| Relative Humidity | 20~95%RH @ 0~40°C (Non condensing) |
| Altitude | Less than 1500m,derating required when>1500m |
| Noise level | Less than 58dB at 1 Meter |
| Alarms | |
|---|---|
| Battery mode | Beeping every 4 seconds |
| Low Battery | Beeping every second |
| Overload | Beeping twice every second |
| Fault | Continously beeping |
| Indicators | |
|---|---|
| LED Display(LED version) | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault |
| LCD Display(LCD version) | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time |
| Battery | |
|---|---|
| Battery Voltage | ±120Vdc |
| Typical recharge time | 6~8 hours (to 90% of full capacity) |
| Charging current (Max) | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) |
| Standard | |
|---|---|
| Safety | IEC/EN62040-1,IEC/EN62477-1 |
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
| Physical | |
|---|---|
| Weight | 18 Kg |
| Height | 86.5 mm |
| Width | 440 mm |
| Length | 625 mm |
Features
- Cold start
- Parallel kit default
- High power density
- Generator compatible
- Wide input frequency range
- Self-testing when UPS startup
- Intelligent fan speed regulation
- Maximum charging current up to 10A
- Wide input voltage range:110~286Vac
- ECO mode operation for energy saving
- LCD supports Rack/Tower convertible design
- Online double conversion with full digital control
- N+X parallel redundancy, support maximum 4 units in parallel
- Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
- Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
- Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Line Interactive UPS -PLS Series
Online 3:1 Transformer less UPS
VRLA AGM
Support Center
Our dedicated support team ensures 24/7 assistance, providing technical support, addressing queries, and receiving feedback at any time. We are just one call away.
Product Warranty
Register your Enerbyte Tech product today to activate your warranty coverage and ensure full manufacturer protection for your investment.
RMA Registration
Upgrading, refurbishing, or experiencing a fault? Register here for a Return Merchandise Authorization and our team will guide you through the repair or replacement process.
Extended Warranty
Extend the warranty period of your Enerbyte Tech product and enjoy long-term peace of mind. More coverage means more protection for your critical power systems.