Online 3:3 Transformer less UPS
The 3:3 transformer‑less UPS combines compact design with advanced functionality, delivering an output power factor of up to 1 and on‑line efficiency of 95.6% for reliable performance with minimal energy loss. Capable of handling inductive and capacitive loads without derating, it supports parallel operation of up to six units for scalability. Its modular design allows easy front‑side maintenance, while fan redundancy and speed control enhance reliability. With on‑line double conversion and high‑frequency technology, it covers capacities from 10 to 1000 KVA. User‑friendly features include one‑click upgrades via upper computer software and comprehensive circuit breaker configurations for seamless control of mains, bypass, maintenance, and output, making it an efficient and flexible solution for critical environments.
Choose your Model
Technical Specification
POWERON Three Phase 10KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 10000VA/10000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Output Waveform | Pure Sine wave |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/ 240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/ 44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~ 34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 129 Kg |
| Height | 868 mm |
| Width | 250 mm |
| Length | 900 mm |
Technical Specification
POWERON Three Phase 15KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 15000VA/15000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Output Waveform | Pure Sine wave |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Efficiency | up to 95.6% |
| Environment | |
|---|---|
| Operating Temperature | 0°C ~ 40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 186 Kg |
| Height | 868 mm |
| Width | 250 mm |
| Length | 900 mm |
Technical Specification
POWERON Three Phase 20KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 20000VA/20000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Output Waveform | Pure Sine wave |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0℃~40℃ |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 187 Kg |
| Height | 868 mm |
| Width | 250 mm |
| Length | 900 mm |
Technical Specification
POWERON Three Phase 30KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 30000VA/30000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Output Waveform | Pure Sine wave |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 236 Kg |
| Height | 868 mm |
| Width | 250 mm |
| Length | 900 mm |
Technical Specification
POWERON Three Phase 40KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 40000VA/40000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Output Waveform | Pure Sine wave |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Efficiency | up to 95.6% |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 239 |
| Height | 868 |
| Width | 250 |
| Length | 890 |
Technical Specification
POWERON Three Phase 50KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 50000VA/50000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 80 |
| Height | 868 |
| Width | 250 |
| Length | 828 |
Technical Specification
POWERON Three Phase 60KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 60000VA/60000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Output Waveform | Pure Sine wave |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 83 |
| Height | 868 |
| Width | 250 |
| Length | 890 |
Technical Specification
POWERON Three Phase 80KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 80000VA/80000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Output Waveform | Pure Sine wave |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 144 |
| Height | 1200 |
| Width | 442 |
| Length | 850 |
Technical Specification
POWERON Three Phase 100KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 100000VA/100000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Efficiency | up to 95.6% |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Output Waveform | Pure Sine wave |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 147 |
| Height | 1200 |
| Width | 442 |
| Length | 850 |
Technical Specification
POWERON Three Phase 120KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 120000VA/120000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 40% load:138~485Vac; Full load:342~485Vac |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | Less than 3% |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | 50 Hz or 60 Hz (setting value) |
| Harmonic distortion (THD) | < 2% linear load and < 4% non-linear load |
| Power Factor | 1.0 |
| Output Waveform | Pure Sine wave |
| Efficiency | up to 95.6% |
| Overload Operation | 110% for 60 min; 125% for 10 min; 150 for 1 min |
| Output frequency synchronization | synchronize with input; when input frequency < ±10% (±1%/±2%/±4%/±5% optional), output (50/60±0.1)Hz. |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| System Features | |
|---|---|
| Communication interface | USB, RS485, Parallel, Relay card(optional), SNMP(optional), Battery temperature sensor(optional), dry contact(EPO_NC, EPO_NO, BAT_SW, BACKFEED or BAT_DRV) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 15 |
| Physical | |
|---|---|
| Weight | 152 |
| Height | 1200 |
| Width | 442 |
| Length | 850 |
Technical Specification
POWERON Three Phase 160KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 160000VA/160000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 95.6% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 65dB |
| System Features | |
|---|---|
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 45 |
| Physical | |
|---|---|
| Weight | 200 |
| Height | 1200 |
| Width | 442 |
| Length | 850 |
Technical Specification
POWERON Three Phase 200KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 200000VA/200000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Operating frequency range | 40Hz-70Hz |
| Bypass voltage range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 96% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 65dB |
| System Features | |
|---|---|
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 80 |
| Physical | |
|---|---|
| Weight | 342 |
| Height | 1600 |
| Width | 600 |
| Length | 850 |
Technical Specification
POWERON Three Phase 250KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 250000VA/250000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Bypass frequency range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 96% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 65dB |
| System Features | |
|---|---|
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 100 |
| Physical | |
|---|---|
| Weight | 385 |
| Height | 1600 |
| Width | 600 |
| Length | 850 |
Technical Specification
POWERON Three Phase 300KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 300000VA/300000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Bypass frequency range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 96% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 68dB |
| System Features | |
|---|---|
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 100 |
| Physical | |
|---|---|
| Weight | 401 |
| Height | 1600 |
| Width | 600 |
| Length | 850 |
Technical Specification
POWERON Three Phase 400KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 400000VA/400000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Bypass frequency range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Efficiency | up to 96% |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Altitude | < 68dB |
| System Features | |
|---|---|
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 140 |
| Physical | |
|---|---|
| Weight | 542 |
| Height | 2000 |
| Width | 600 |
| Length | 850 |
Technical Specification
POWERON Three Phase 500KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 500000VA/500000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Bypass frequency range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 96% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 70dB |
| System Features | |
|---|---|
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 180 |
| Physical | |
|---|---|
| Weight | 800 |
| Height | 2000 |
| Width | 1200 |
| Length | 850 |
Technical Specification
POWERON Three Phase 600KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 600000VA/600000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Bypass frequency range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Efficiency | up to 96% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 70dB |
| System Features | |
|---|---|
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 200 |
| Physical | |
|---|---|
| Weight | 890 |
| Height | 2000 |
| Width | 1200 |
| Length | 850 |
Technical Specification
POWERON Three Phase 800KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 800000VA/800000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Bypass frequency range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 96% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 73dB |
| System Features | |
|---|---|
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 280 |
| Physical | |
|---|---|
| Weight | 1450 |
| Height | 2000 |
| Width | 2000 |
| Length | 850 |
Technical Specification
POWERON Three Phase 1000KVA Online Double Conversion UPS with 1pf, Semi Modular Concept Design
Capacity (VA/Watts): 1000000VA/1000000W
| Input | |
|---|---|
| Nominal voltage | 380/400/415; 3Ph+N+PE |
| Operating voltage range | 138~305Vac for 40% load; 305~485Vac for 100% load |
| Operating frequency range | 40Hz-70Hz |
| Power Factor | ≥0.99 |
| Harmonic distortion (THDi) | ≤ 3%(100% linear load) |
| Bypass frequency range | Max. voltage: 220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) Min. voltage: -45% (optional-10%, -15%, -20%, -30%) |
| Generator input | Support |
| Output | |
|---|---|
| Output voltage | 380/400/415; 3Ph+N+PE |
| Output frequency | Synchronize with input, when the input frequency > ±10% (±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) / (50/60±0.1%)Hz |
| Harmonic distortion (THD) | ≤ 1% with linear load ≤ 3% with non linear load |
| Power Factor | 1.0 |
| Voltage Regulation | ± 1% |
| Efficiency | up to 96% |
| Overload Operation | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Environment | |
|---|---|
| Operating Temperature | 0°C~40°C |
| Storage Temperature | – 25°C ~ 55°C |
| Relative Humidity | 0 ~ 95% (non condensing) |
| Noise level | < 75 dB |
| System Features | |
|---|---|
| Transfer time | Utility to Battery : 0ms; Utility to Bypass: 0ms |
| Overload | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. 135% overload for long term; >1000% overload for 100 ms |
| Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) |
| Battery | |
|---|---|
| Battery Voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs define, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8;) |
| Charging current (Max) | 340 |
| Physical | |
|---|---|
| Weight | 1600 |
| Height | 2000 |
| Width | 2000 |
| Length | 850 |
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 95.6%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design ,easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 96%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design, easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 96%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software ( LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design, easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 96%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software (LCD excluded)
- Completed CB configurations for mains ,bypass ,maintenance and output
- Modular-concept design, easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 96%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software (LCD excluded)
- Completed CB configurations for mains, bypass, maintenance and output
- Modular-concept design, easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 96%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software (LCD excluded)
- Completed CB configurations for mains, bypass, maintenance and output
- Modular-concept design, easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 96%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software (LCD excluded)
- Completed CB configurations for mains, bypass, maintenance and output
- Modular-concept design, easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Features
- Output PF up to 1
- Parallel up to 6 units
- On line efficiency up to 96%
- Compact sizes with limited foot-prints
- Fan redundancy design, speed Control
- No derating for PF≥0.5 inductive load and capacitive load
- On-line double conversion and high frequency UPS 10-1000KVA
- One-click upgradation by upper computer software (LCD excluded)
- Completed CB configurations for mains, bypass, maintenance and output
- Modular-concept design, easily maintenance by replacing power modules from front side (no need side and rear maintenances)
Online 3:1 Transformer less UPS
Online 3:3 Transformer based UPS
Servo Prime Series
Support Center
Our dedicated support team ensures 24/7 assistance, providing technical support, addressing queries, and receiving feedback at any time. We are just one call away.
Product Warranty
Register your Enerbyte Tech product today to activate your warranty coverage and ensure full manufacturer protection for your investment.
RMA Registration
Upgrading, refurbishing, or experiencing a fault? Register here for a Return Merchandise Authorization and our team will guide you through the repair or replacement process.
Extended Warranty
Extend the warranty period of your Enerbyte Tech product and enjoy long-term peace of mind. More coverage means more protection for your critical power systems.