Online 1:1 Transformer less UPS

The transformer‑less single‑phase input, single‑phase output online double conversion UPS delivers seamless power protection with advanced features including cold start capability, generator compatibility, and a hot‑swappable battery system for easy maintenance without interruption. Its rack/tower convertible design and versatile LCD interface make it adaptable for diverse installations, while a high input power factor of 0.99 with PFC and ECO mode operation maximize energy efficiency. With a wide input voltage range, selectable output options, and a smart charger to optimize battery performance, the system ensures flexibility and reliability. Multiple communication interfaces and robust safeguards against short circuits, overloads, and overheating further enhance its dependability, making it ideal for critical applications requiring continuous and efficient power management.

 

Choose your Model

Technical Specification

Single Phase 230VAC-1000Va E series Online Double Conversion UPS, Rack Model

Capacity (VA/Watts): 1000VA/900W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~300Vac (176~280Vac @ 100% load)
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤3% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass4ms (Typical)
Output WaveformPure Sinewave
Output Frequency Line Mode46~54Hz or 56~64Hz
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 50dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery type & number9AH, 2nos
Typical recharge time4 hours (to 90% of full capacity)
Charging voltage27.4Vdc ±1%
Charging current (Max)1A
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight11.3 Kg
Height86.5 mm
Width440 mm
Length325 mm

Features

  • Cold start
  • Generator compatible
  • Hot-Swappable battery design
  • Rack/Tower convertible design
  • Intelligent fan speed regulation
  • Input power factor 0.99 with PFC
  • Load segment settable (Optional)
  • Emergency power off function (EPO)
  • Wide input voltage range:110~300Vac
  • ECO mode operation for energy saving
  • Versatile LCD human-computer interface
  • Online double conversion with full digital control
  • Selectable output voltage: 208/220/230/240Vac
  • Smart charger design for optimized battery performance
  • Maximum charging current can be expanded to 12A (Long run unit)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-1000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger

Capacity (VA/Watts): 1000VA/900W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~300Vac (176~280Vac @ 100% load)
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤3% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass4ms (Typical)
Output WaveformPure Sinewave
Output Frequency Line Mode46~54Hz or 56~64Hz
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 50dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Typical recharge time4 hours (to 90% of full capacity)
Charging voltage27.4Vdc ±1%
Charging current (Max)6A/12A
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight5.6 Kg
Height86.5 mm
Width440 mm
Length325 mm
 

Features

  • Cold start
  • Generator compatible
  • Hot-Swappable battery design
  • Rack/Tower convertible design
  • Intelligent fan speed regulation
  • Input power factor 0.99 with PFC
  • Load segment settable (Optional)
  • Emergency power off function (EPO)
  • Wide input voltage range:110~300Vac
  • ECO mode operation for energy saving
  • Versatile LCD human-computer interface
  • Online double conversion with full digital control
  • Selectable output voltage: 208/220/230/240Vac
  • Smart charger design for optimized battery performance
  • Maximum charging current can be expanded to 12A (Long run unit)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-2000Va Online Double Conversion UPS, Rack/Tower Convertible Model

Capacity (VA/Watts): 2000VA/1800W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~300Vac (176~280Vac @ 100% load)
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Power Factor0.9
Voltage Regulation± 1%
Output Frequency Line Mode46~54Hz or 56~64Hz
Output Frequency Bat. Mode(50/60±0.1%)Hz
AC Voltage Regulation Batt Mode0ms
Frequency Range Batt Mode4ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
Harmonic distortion (THD)≤3% Linear load ≤5% Non linear load
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass4ms (Typical)
Output WaveformPure Sinewave
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
Altitude1500m
Noise levelLess than 50dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery type & number9AH & 4nos
Typical recharge time4 hours (to 90% of full capacity)
Charging voltage54.8Vdc ±1%
Charging current (Max)1A
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight19.5 Kg
Height86.5 mm
Width440 mm
Length460 mm
 

Features

  • Cold start
  • Generator compatible
  • Hot-Swappable battery design
  • Rack/Tower convertible design
  • Intelligent fan speed regulation
  • Input power factor 0.99 with PFC
  • Load segment settable (Optional)
  • Emergency power off function (EPO)
  • Wide input voltage range:110~300Vac
  • ECO mode operation for energy saving
  • Versatile LCD human-computer interface
  • Online double conversion with full digital control
  • Selectable output voltage: 208/220/230/240Vac
  • Smart charger design for optimized battery performance
  • Maximum charging current can be expanded to 12A (Long run unit)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-2000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger

Capacity (VA/Watts): 2000VA/1800W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~300Vac (176~280Vac @ 100% load)
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤3% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Output Frequency Line Mode46~54Hz or 56~64Hz
Output Frequency Bat. Mode(50/60±0.1%)Hz
AC Voltage Regulation Batt Mode0ms
Frequency Range Batt Mode4ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 50dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Typical recharge time4 hours (to 90% of full capacity)
Charging voltage54.8Vdc ±1%
Charging current (Max)6A/12A
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight10.5 Kg
Height86.5 mm
Width440 mm
Length600 mm
 

Features

  • Cold start
  • Generator compatible
  • Hot-Swappable battery design
  • Rack/Tower convertible design
  • Intelligent fan speed regulation
  • Input power factor 0.99 with PFC
  • Load segment settable (Optional)
  • Emergency power off function (EPO)
  • Wide input voltage range:110~300Vac
  • ECO mode operation for energy saving
  • Versatile LCD human-computer interface
  • Online double conversion with full digital control
  • Selectable output voltage: 208/220/230/240Vac
  • Smart charger design for optimized battery performance
  • Maximum charging current can be expanded to 12A (Long run unit)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-3000Va Online Double Conversion UPS, Rack/Tower Convertible Model

Capacity (VA/Watts): 3000VA/2700W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~300Vac (176~280Vac @ 100% load)
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤3% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass4ms (Typical)
Output WaveformPure Sinewave
Output Frequency Line Mode46~54Hz or 56~64Hz
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 50dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery type & number9AH & 6nos
Typical recharge time4 hours (to 90% of full capacity)
Charging voltage82.2Vdc ±1%
Charging current (Max)1A
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight26 Kg
Height86.5 mm
Width440 mm
Length600 mm
 

Features

  • Cold start
  • Generator compatible
  • Hot-Swappable battery design
  • Rack/Tower convertible design
  • Intelligent fan speed regulation
  • Input power factor 0.99 with PFC
  • Load segment settable (Optional)
  • Emergency power off function (EPO)
  • Wide input voltage range:110~300Vac
  • ECO mode operation for energy saving
  • Versatile LCD human-computer interface
  • Online double conversion with full digital control
  • Selectable output voltage: 208/220/230/240Vac
  • Smart charger design for optimized battery performance
  • Maximum charging current can be expanded to 12A (Long run unit)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-3000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger

Capacity (VA/Watts): 3000VA/2700W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~300Vac (176~280Vac @ 100% load)
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤3% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass4ms (Typical)
Output WaveformPure Sinewave
Output Frequency Line Mode46~54Hz or 56~64Hz
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
Altitude1500m
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Typical recharge time4 hours (to 90% of full capacity)
Charging voltage82.2Vdc ±1%
Charging current (Max)6A/12A
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight11 Kg
Height86.5 mm
Width440 mm
Length600 mm
 

Features

  • Cold start
  • Generator compatible
  • Hot-Swappable battery design
  • Rack/Tower convertible design
  • Intelligent fan speed regulation
  • Input power factor 0.99 with PFC
  • Load segment settable (Optional)
  • Emergency power off function (EPO)
  • Wide input voltage range:110~300Vac
  • ECO mode operation for energy saving
  • Versatile LCD human-computer interface
  • Online double conversion with full digital control
  • Selectable output voltage: 208/220/230/240Vac
  • Smart charger design for optimized battery performance
  • Maximum charging current can be expanded to 12A (Long run unit)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-6000Va Online Double Conversion UPS, Tower Model

Capacity (VA/Watts): 6000VA/5400W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~286Vac
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Bypass voltage rangeMax.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%)
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤2% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass0ms
Output WaveformPure Sinewave
Overload Line ModeLoad≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately
Overload Bypass Mode40A (Breaker)
Efficiency93.5%
Output Frequency Line Mode±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 55dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery Voltage±120Vdc
Battery type & number9AH & 20nos
Typical recharge time6~8 hours (to 90% of full capacity)
Charging current (Max)1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight70 Kg
Height720 mm
Width191 mm
Length460 mm
 

Features

  • Cold start
  • Generator compatible
  • Wide input frequency range
  • Self-testing when UPS startup
  • Intelligent fan speed regulation
  • Maximum charging current up to 10A
  • Wide input voltage range:110~286Vac
  • ECO mode operation for energy saving
  • Design with maintenance switch (Optional)
  • Selectable output voltage:208/220/230/240Vac
  • Online double conversion with full digital control
  • N+X parallel redundancy, support maximum 4 units in parallel
  • Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-6000Va Online Double Conversion UPS, Tower Model with extended charger

Capacity (VA/Watts): 6000VA/5400W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~286Vac
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Bypass voltage rangeMax.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%)
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤2% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass0ms
Output WaveformPure Sinewave
Overload Line ModeLoad≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately
Overload Bypass Mode40A (Breaker)
Efficiency93.5%
Output Frequency Line Mode±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 55dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery Voltage±96/±108/±120Vdc (Adjustable)
Typical recharge time6~8 hours (to 90% of full capacity)
Charging current (Max)1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight12.5 Kg
Height337 mm
Width191 mm
Length460 mm
 

Features

  • Cold start
  • Generator compatible
  • Wide input frequency range
  • Self-testing when UPS startup
  • Intelligent fan speed regulation
  • Maximum charging current up to 10A
  • Wide input voltage range:110~286Vac
  • ECO mode operation for energy saving
  • Design with maintenance switch (Optional)
  • Selectable output voltage:208/220/230/240Vac
  • Online double conversion with full digital control
  • N+X parallel redundancy, support maximum 4 units in parallel
  • Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-6000Va Online Double Conversion UPS, Rack/Tower Convertible Model with extended charger

Capacity (VA/Watts): 6000VA/5400W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~286Vac
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Bypass voltage rangeMax.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%)
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤2% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass0ms
Output WaveformPure Sinewave
Overload Line ModeLoad≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately
Overload Bypass Mode40A (Breaker)
Efficiency94%
Output Frequency Line Mode±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 55dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery Voltage±120Vdc
Typical recharge time6~8 hours (to 90% of full capacity)
Charging current (Max)1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight16 Kg
Height86.5 mm
Width440 mm
Length625 mm
 

Features

  • Cold start
  • Parallel kit default
  • High power density
  • Generator compatible
  • Wide input frequency range
  • Self-testing when UPS startup
  • Intelligent fan speed regulation
  • Maximum charging current up to 10A
  • Wide input voltage range:110~286Vac
  • ECO mode operation for energy saving
  • LCD supports Rack/Tower convertible design
  • Online double conversion with full digital control
  • N+X parallel redundancy, support maximum 4 units in parallel
  • Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-10000Va Online Double Conversion UPS, Tower Model

Capacity (VA/Watts): 10000VA/9000W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~286Vac
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Bypass voltage rangeMax.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%)
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤2% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass0ms
Output WaveformPure Sinewave
Overload Line ModeLoad≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately
Overload Bypass Mode63A (Breaker)
Efficiency93.5%
Output Frequency Line Mode±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 58dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery Voltage±120Vdc
Typical recharge time6~8 hours (to 90% of full capacity)
Charging current (Max)1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight71.5 Kg
Height720 mm
Width191 mm
Length460 mm
 

Features

  • Cold start
  • Generator compatible
  • Wide input frequency range
  • Self-testing when UPS startup
  • Intelligent fan speed regulation
  • Maximum charging current up to 10A
  • Wide input voltage range:110~286Vac
  • ECO mode operation for energy saving
  • Design with maintenance switch (Optional)
  • Selectable output voltage:208/220/230/240Vac
  • Online double conversion with full digital control
  • N+X parallel redundancy, support maximum 4 units in parallel
  • Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-10000Va Online Double Conversion UPS, Tower Model with extended charger

Capacity (VA/Watts): 10000VA/9000W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~286Vac
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Bypass voltage rangeMax.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%)
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤2% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass0ms
Output WaveformPure Sinewave
Overload Line ModeLoad≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately
Overload Bypass Mode63A (Breaker)
Efficiency93.5%
Output Frequency Line Mode±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery Voltage±96/±108/±120Vdc (Adjustable)
Typical recharge time6~8 hours (to 90% of full capacity)
Charging current (Max)1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight14 Kg
Height337 mm
Width191 mm
Length460 mm
 

Features

  • Cold start
  • Generator compatible
  • Wide input frequency range
  • Self-testing when UPS startup
  • Intelligent fan speed regulation
  • Maximum charging current up to 10A
  • Wide input voltage range:110~286Vac
  • ECO mode operation for energy saving
  • Design with maintenance switch (Optional)
  • Selectable output voltage:208/220/230/240Vac
  • Online double conversion with full digital control
  • N+X parallel redundancy, support maximum 4 units in parallel
  • Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Technical Specification

Single Phase 230VAC-10000Va Online Double Conversion UPS, Rack/Tower Convertible Model

Capacity (VA/Watts): 10000VA/9000W

Input 
Nominal voltage208/220/230/240Vac
Operating voltage range110~286Vac
Operating frequency range40~70Hz (50/60Hz Auto-Sensing)
Power Factor≥0.99
Bypass voltage rangeMax.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%)
Output 
Output voltage208/220/230/240Vac
Crest factor3:1
Harmonic distortion (THD)≤2% Linear load ≤5% Non linear load
Power Factor0.9
Voltage Regulation± 1%
Transfer Time AC Mode to Batt Mode0ms
Transfer Time Inverter to Bypass0ms
Output WaveformPure Sinewave
Overload Line ModeLoad≤110% last 60min; ≤125% last 10min; ≤150% last 1min;>150% turn to bypass mode immediately
Overload Bypass Mode63A (Breaker)
Efficiency94%
Output Frequency Line Mode±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional)
Output Frequency Bat. Mode(50/60±0.1%)Hz
Environment 
Operating Temperature0°C ~ 40°C
Storage Temperature-25°C ~ 55°C
Relative Humidity20~95%RH @ 0~40°C (Non condensing)
AltitudeLess than 1500m,derating required when>1500m
Noise levelLess than 58dB at 1 Meter
Alarms 
Battery modeBeeping every 4 seconds
Low BatteryBeeping every second
OverloadBeeping twice every second
FaultContinously beeping
Indicators 
LED Display(LED version)Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault
LCD Display(LCD version)Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Battery 
Battery Voltage±120Vdc
Typical recharge time6~8 hours (to 90% of full capacity)
Charging current (Max)1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity)
Standard 
SafetyIEC/EN62040-1,IEC/EN62477-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Physical 
Weight18 Kg
Height86.5 mm
Width440 mm
Length625 mm
 

Features

  • Cold start
  • Parallel kit default
  • High power density
  • Generator compatible
  • Wide input frequency range
  • Self-testing when UPS startup
  • Intelligent fan speed regulation
  • Maximum charging current up to 10A
  • Wide input voltage range:110~286Vac
  • ECO mode operation for energy saving
  • LCD supports Rack/Tower convertible design
  • Online double conversion with full digital control
  • N+X parallel redundancy, support maximum 4 units in parallel
  • Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
  • Multiple communication interface:RS232 (USB/EPO/Relay card/SNMP card optional)
  • Multiple protection function : short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
 

Line Interactive UPS -PLS Series

Online 3:1 Transformer less UPS

VRLA AGM

Support Center

Our dedicated support team ensures 24/7 assistance, providing technical support, addressing queries, and receiving feedback at any time. We are just one call away.

Product Warranty

Register your Enerbyte Tech product today to activate your warranty coverage and ensure full manufacturer protection for your investment.

RMA Registration

Upgrading, refurbishing, or experiencing a fault? Register here for a Return Merchandise Authorization and our team will guide you through the repair or replacement process.

Extended Warranty

Extend the warranty period of your Enerbyte Tech product and enjoy long-term peace of mind. More coverage means more protection for your critical power systems.

Scroll to Top