🔍 Hover to zoom
Line Interactive UPS
Line Interactive UPS
PLS Series
This UPS is specifically designed for personal computers, offering multiple functions to suit your needs. Its lightweight, compact design is ideal for limited workspaces. Equipped with both a boost and buck AVR, it stabilizes input voltage, ensuring reliable performance. Additionally, the built-in DC start function allows the UPS to power up even without an AC power supply.
Microcontroller Based
Compact Design
Boost & Buck AVR
Choose your Model
Technical Specification
PLS 117 650VA
| Parameter | PLS 117 650VA |
|---|---|
| Capacity | 650VA / 390W |
| Input Voltage Range | 140V – 300V (AVR Mode) |
| Input Frequency | 50/60 Hz ± 5 Hz (Auto Sensing) |
| Output Voltage | 220/230/240 VAC ± 10% |
| Output Frequency | 50/60 Hz ± 1 Hz |
| Transfer Time | ≤ 4ms (Typical) |
| Waveform (Battery) | Simulated Sine Wave |
| Battery Type | 12V / 7Ah Sealed Lead Acid |
| Battery Quantity | 1 × 12V/7Ah |
| Typical Backup Time | 5–8 min (full load) |
| Charging Time | ≤ 8 hours (90% capacity) |
| Output Receptacles | 4 × IEC C13 |
| Communication Port | USB / RJ-45 |
| Operating Temperature | 0°C – 40°C |
| Relative Humidity | 0 – 90% (Non-condensing) |
| Dimensions (mm) | 100 × 190 × 260 |
| Weight | 4.5 kg |
| Certifications | CE, RoHS, IEC 62040 |
| Parameter | PLS 117 1000VA |
|---|---|
| Capacity | 1000VA / 600W |
| Input Voltage Range | 140V – 300V (AVR Mode) |
| Input Frequency | 50/60 Hz ± 5 Hz (Auto Sensing) |
| Output Voltage | 220/230/240 VAC ± 10% |
| Output Frequency | 50/60 Hz ± 1 Hz |
| Transfer Time | ≤ 4ms (Typical) |
| Waveform (Battery) | Simulated Sine Wave |
| Battery Type | 12V / 7Ah Sealed Lead Acid |
| Battery Quantity | 1 × 12V/7Ah |
| Typical Backup Time | 5–8 min (full load) |
| Charging Time | ≤ 8 hours (90% capacity) |
| Output Receptacles | 4 × IEC C13 |
| Communication Port | USB / RJ-45 |
| Operating Temperature | 0°C – 40°C |
| Relative Humidity | 0 – 90% (Non-condensing) |
| Dimensions (mm) | 100 × 190 × 290 |
| Weight | 6.0 kg |
| Certifications | CE, RoHS, IEC 62040 |
| Parameter | PLS 117 1500VA |
|---|---|
| Capacity | 1500VA / 900W |
| Input Voltage Range | 140V – 300V (AVR Mode) |
| Input Frequency | 50/60 Hz ± 5 Hz (Auto Sensing) |
| Output Voltage | 220/230/240 VAC ± 10% |
| Output Frequency | 50/60 Hz ± 1 Hz |
| Transfer Time | ≤ 4ms (Typical) |
| Waveform (Battery) | Simulated Sine Wave |
| Battery Type | 12V / 7Ah Sealed Lead Acid |
| Battery Quantity | 2 × 12V/7Ah |
| Typical Backup Time | 5–8 min (full load) |
| Charging Time | ≤ 8 hours (90% capacity) |
| Output Receptacles | 6 × IEC C13 |
| Communication Port | USB / RJ-45 |
| Operating Temperature | 0°C – 40°C |
| Relative Humidity | 0 – 90% (Non-condensing) |
| Dimensions (mm) | 130 × 230 × 330 |
| Weight | 9.5 kg |
| Certifications | CE, RoHS, IEC 62040 |
| Parameter | PLS 117 2000VA |
|---|---|
| Capacity | 2000VA / 1200W |
| Input Voltage Range | 140V – 300V (AVR Mode) |
| Input Frequency | 50/60 Hz ± 5 Hz (Auto Sensing) |
| Output Voltage | 220/230/240 VAC ± 10% |
| Output Frequency | 50/60 Hz ± 1 Hz |
| Transfer Time | ≤ 4ms (Typical) |
| Waveform (Battery) | Simulated Sine Wave |
| Battery Type | 12V / 7Ah Sealed Lead Acid |
| Battery Quantity | 2 × 12V/7Ah |
| Typical Backup Time | 5–8 min (full load) |
| Charging Time | ≤ 8 hours (90% capacity) |
| Output Receptacles | 6 × IEC C13 |
| Communication Port | USB / RJ-45 |
| Operating Temperature | 0°C – 40°C |
| Relative Humidity | 0 – 90% (Non-condensing) |
| Dimensions (mm) | 130 × 230 × 360 |
| Weight | 11.0 kg |
| Certifications | CE, RoHS, IEC 62040 |
Boost & Buck AVR
Automatically stabilizes input voltage without switching to battery, extending battery life and ensuring consistent output.
Microcontroller Based
Advanced microcontroller ensures intelligent power management, fault detection, and reliable system control.
Compact & Lightweight
Space-saving tower design fits perfectly on your desk or under workstations with limited space.
LCD Status Display
Clear LCD panel shows input/output voltage, battery level, load percentage, and fault alerts at a glance.
DC Cold Start
Built-in DC start function allows the UPS to power connected devices even without AC power supply.
Overload & Short Circuit Protection
Multiple protection layers safeguard connected equipment from overloads, surges, and short circuits.
USB Communication Port
USB interface enables communication with your computer for automatic shutdown during prolonged outages.
Auto Restart
Automatically restores power to connected devices when utility power returns after an outage.









Online Double Conversion UPS
True online UPS for critical applications requiring zero transfer time.
View Product →

VRLA Batteries
Sealed lead acid replacement batteries for UPS systems.
View Product →

Air Cooled Voltage Stabilizer
High precision servo voltage stabilizers for industrial use.
View Product →
PLS Series Datasheet
PDF · 2.4 MB · Updated Mar 2025
User Manual – PLS Series
PDF · 5.1 MB · Updated Jan 2025
CE Declaration of Conformity
PDF · 0.8 MB · Updated Dec 2024
Quick Installation Guide
PDF · 1.2 MB · Updated Feb 2025
Enquire Now
Submit your questions and receive prompt and detailed responses.